May 2023| Volume 02 | Issue 01 | Pages 12-20
Future Energy
Open Access Journal Journal homepage: https://fupubco.com/fuen
ISSN 2832-0328
Future Publishing LLC
https://doi.org/10.55670/fpll.fuen.2.2.2
Article
A feasibility study and cost-benefit analysis of
an off-grid hybrid system for a remote area
electrification
Upma Singh12*, Mohammad Rizwan!
1Department of Electrical Engineering, Delhi Technological University, Delhi 110042, India
?Department of Electronics and Communication Engineering, Maharaja Surajmal Institute of Technology, Delhi 110058,
India
ARTICLE INFO
ABSTRACT
Article history:
Received 10 October 2022
Received in revised form
12 November 2022
Accepted 22 November 2022
Keywords:
Renewable Energy, HOMER, Biogas,
Solar Photovoltaic,
Hybrid Renewable Energy Sources (HRES)
*Corresponding author
Email address:
upma@msit.in
DOI: 10.55670/fpll.fuen.2.2.2
Off-grid power production utilizing renewable sources of power has become
more significant and viable to meet the limited demands of remote locations.
The primary goal of this study is to develop an economic and optimal hybrid
PV/Biogas configuration for power production for rural common facilities,
including one Primary school, Junior school, and Panchayat Ghar buildings of
Sarai Jairam village in Uttar Pradesh, India. Data on the electric load was
gathered for two schools and Panchayat Ghar. The PV/biogas hybrid
configuration was designed utilizing the Hybrid Optimization Model for Electric
Renewable (HOMER), and techno-economic analysis is carried out to fulfill the
load requirements. The available biomass potential and the data on solar
irradiance of the study area were utilized in the HOMER software to carry out
the analysis. The HOMER analysis produced a solution that included total net
present cost (NPC) and cost of electricity (COE), and these results were then
further improved using sensitivity analysis. The sensitivity analysis employed
sensitivity parameters like biomass potential, biomass pricing, solar irradiance,
and variation in loads. Based on the NPC and COE, this analysis evaluates the
system performance and demonstrates that it is techno-economically feasible.
1. Introduction
energy, and expanding the grid is not practical. Furthermore,
The unavailability or shortage of electrical networks in
remote locations, the excessive cost of grid extension, and the
harsh topography frequently lead to exploring other
alternatives. One of the most promising approaches to meet
these areas’ need for electrification now involves standalone
hybrid systems [1]. The grid-connected electricity for power
delivery does not always benefit people. For instance,
individuals who live in isolated villages, distant farms, and
rural locations must rely on autonomous power supply
systems that are based on the burning of fossil fuels [2]. The
issue is that these systems increase greenhouse gas (GHG)
emissions, which in turn lead to air pollution [3]. By utilizing
renewable energy sources like solar, wind, biofuels, and
others, GHG emissions may be decreased. Rural electrification
is crucial to improving the economic and social conditions of
rural residents and, eventually, to the development of the
country [4-5]. The bulk of the population in India lives in
isolated rural regions where they do not have access to grid
those remote locations with grid connections only receive a
restricted supply once every six to nine hours [6]. In addition,
using a diesel generator to get an electric supply is not a
practical alternative due to the expense of fuel, maintenance,
and operation, as well as the emission of greenhouse gases,
etc [7-8]. Additionally, the Government of India is working to
promote renewable energy sources by offering various
programs, incentives, etc. The Indian government has also set
a target of increasing the amount of electricity produced by
RES to 450 GW by 2022 [9]. Due to the stochastic nature of
RES, a hybrid system that combines two or more sources is a
more advantageous and sustainable alternative [10]. Utilizing
a variety of simulation and optimization tools and
approaches, a great deal of work has been done in this regard.
Flavio Odoi- Yorke et al. examined the possibility of using a
hybrid solar PV/biogas/battery energy system to provide
power to distant areas in Ghana. The objective is to employ
locally accessible renewable energy sources to reduce
12
U. Singh, M. Rizwan/Future Energy
greenhouse gas emissions while achieving a Levelized Cost of
Electricity (LCOE). The results show that in terms of cost and
pollution savings, PV/biogas/battery systems outperform
PV/diesel/battery and diesel-only systems [11]. Endeshaw
Solomon Bayu et al. conducted a study to incorporate wind
turbines, micro-hydro systems, solar photovoltaic (PV)
systems, and battery systems to check the feasibility of hybrid
systems to electrify the remote place [12]. Paul et al.
examined the economic viability and feasibility of utilizing a
hybrid-electricity system in rural areas. The findings show
that, when compared to PV/Diesel Generator (DG)/B and
isolated DG systems, the photovoltaic (PV)/battery (B)
system based on renewable energy (RE) has the lowest net
profit cost (NPC) and cost of energy (COE). Although the COE
and NPC values of the diesel generator (DG) hybrid-electric
system (HES) are lower than those of the PV/DG/B system,
the DG system still emits the most substantial pollution [13].
Similarly, Nyagong Santino et al. evaluated the viability of a
hybrid power system for a remote South Sudanese
community without electricity access. Based on the
community's energy requirements, average energy
consumption profiles were created over the course of a year.
The system was configured and optimized using the HOMER
pro application, and based on the standalone mode of
operation, six potential combinations were modeled and
examined technically and economically. Due to the significant
solar potential, the Battery/DG/PV system has the minimum
Net Present Cost (NPC) and Cost of Energy (COE) and
provides a 22.94% investment return [14].
For the Atacama Desert in Chile, Francisco et al.
conducted a cost-benefit analysis of the TEG-HPV system
under actual environmental and market circumstances. The
economic, electrical, and thermal models of the TEG-HPV
system are constructed and examined in MATLAB. With
regard to system costs, energy losses, ordinal efficiencies of
TEG and PV modules, and their contributions to the
economical viability of TEG-HPV systems, five distinct cases
are taken into consideration. Payback durations for every
scenario are calculated at maximum and minimum PV
temperatures for the Atacama Desert, taking into account the
industrial and residential prices of electricity [15]. Laetitia et
al. conducted a feasibility study with the goal of incorporating
renewable energy sources into Popova Island's energy
system. It takes an analytical strategy that entails using an
energy systems model and the Monte Carlo method before
assessing the financial results [16]. Ahmad et al. investigated
the feasibility of meeting the load demand with the best
system that produces the least amount of CO2 and net present
cost (NPC) emissions. The modeling results demonstrate that
the NPC of the proposed grid/PV system is more sufficient
than other configurations at the present grid tariff, resulting
in a renewable proportion of more than over 50%, a payback
period of 17 years, and a 54.3% decrease in COz. The
outcomes further demonstrate that the integration of a 62 kW
PV array with the primary grid is the optimal configuration
that results in a minimal COE of 0.0688 $/kWh and sale back
power of 9.16% of Al Baha University's total electricity
consumption [17]. Mohammad Amin et al. developed the best
renewable energy system possible to power a small
community using only renewable energy sources. Like many
remote Iranian communities, this one experiences regular
May 2023] Volume 02 | Issue 02| Pages 12-20
power shortages. A hybrid stand-alone and on-grid
renewable energy system using fuel cells, biogas generators,
wind turbines, and photovoltaics is suggested. In addition to
the fuel cells, batteries, a hydrogen tank, an electrolyzer or
reformer, and other backup and storage components are
employed. The major objective is to identify the best design
that can fulfill the demand for power while being acceptable
from an environmental and an economic standpoint. The
findings demonstrate that the cheapest option is to use
biogas, wind, and solar rather than adding a fuel cell to this
design would raise prices by 33-37% while simultaneously
increasing the scalability of the system [18]. It is clearly
revealed from the literature that a hybrid energy system with
a diesel engine has several benefits over one that is solely
powered by a diesel engine, including a longer engine
lifespan, lower O&M (Operation and Maintenance) costs,
lower fuel consumption and less of an adverse impact on the
environment. Such systems still depend on fossil fuel, which
is unfriendly to the environment and necessitates logistical
arrangements for delivering the fuel to the community, which
is the problem with them. Local fuel availability is frequently
poor because of expensive transit expenses and theft danger.
The diesel engine may be totally replaced with a biogas engine
to solve the aforementioned issues, and its fuel can be
produced locally in a limited digester. Utilizing locally
generated biogas from dung can resolve issues associated
with diesel fuel. Furthermore, the literature survey also
indicates that HRES is a more reliable and cost-effective
source of power than conventional grid systems.
Additionally, the aforesaid research mostly focused on
household electrification of rural areas while ignoring the
need for power for schools and panchayat ghar. To the
author's knowledge, there is no thorough study on the
techno-economic analysis of such HRES in using HOMER on
the selected location. Also, the creation of such models relied
on the use of solar and wind energy, and there are only a small
number of studies in which biogas and biomass energy
sources were regarded as important sources for generating
electricity. In this regard, an HRE-based power producing
system is suggested for supplying continuous electricity to
two schools and Panchayat ghar, located in Sarai Jairam
village, district Agra, Uttar Pradesh, India. As a consequence,
the major goal of this study is to offer the most feasible and
most optimized alternative for electrifying panchayat ghar
and primary schools situated in distant areas without access
to grid electricity. To create the HRES, local RES from the
research region is employed. Data on electrical load, solar
radiation and biogas were utilized to apply techno-economic
analysis utilizing HOMER pro simulations based on
sensitivity. The organizational structure of the paper is
planned as follows. Section 2 discusses the method of
modeling of hybrid systems. Section 3 describes the
assessment of electrical load. Section 4 briefly explains the
system design and its assessment. Section 5, contains results
and discussion and Section 6 presents the conclusions.
2. Method of Modeling Hybrid Systems
For the design and construction of an optimum hybrid
system for a rural region, a systematized modeling technique
is an integral step since it ensures that the rural population
has reliable, consistent and dependable access to electricity
13
U. Singh, M. Rizwan/Future Energy
[19]. The HOMER pro software has been utilized as a tool to
identify the set of optimum systems that meet the load
demand under specific system restrictions and input
assumptions [20]. HOMER pro is a distributed power
optimization tool designed by the National Renewable Energy
Laboratory in the United States [21]. Due to the uncertainties,
a sensitivity analysis is conducted to investigate the influence
of input assumptions on the optimization outcomes. Figure 1
depicts the process and proposed framework for system
modeling and analysis. In the current study, a modeling
technique that is shown in the following sections includes a
description of the selected location, an assessment of
renewable energy sources’ potential, electrical load
estimation, and system design and optimization procedure.
Figure 1. Process and proposed framework for system
modeling and analysis
2.1 Location Description
The site for this study was Sarai Jairam village in Uttar
Pradesh, India. The abundance of renewable energy and the
region's strategic significance was taken into consideration
while choosing the location. The location is identified by the
coordinates at the longitude of 780 10.7’E and latitude of 270
20.2’N and time zone (GMT+05:30) from NASA
meteorological data. Figure 2 shows the geographic view of
the research location.
UTTAR PRADESH >
nem mae P
Figure 2. The geographic view of the research location
May 2023| Volume 02 | Issue 02| Pages 12-20
2.2 Assessment of wind and solar resources potential at
the selected site
From NASA meteorological data, the solar and wind
energy data for Sarai Jairam village have been extracted, and
the data are shown in Table 1 with their latitude and
longitude (270 20.2’N, 780 10.7’E), and time stamp
(GMT+05:30). Figure 3 and Figure 4 provide graphical
representations of the specifics of solar radiation throughout
the course of the year and wind data over the same period.
Table 1 provides data on the selected site's annual average
daily radiation (kWh/m2/day), clearness index, and wind
speed (m/s).
Table 1. Average monthly daily radiation, clearness index,
and wind speed
Month Solar Energy (SE) Clearness Wind
(kWh/m?/day) Index Speed
(WS)
(m/s)
Jan 3.670 0.578 4.230
Feb 4.690 0.623 4.690
March 5.590 0.620 5.020
April 6.080 0.589 5.100
May 6.360 0.574 5.250
June 6.010 0.531 5.180
July 4.960 0.444 4.740
Aug 4.540 0.430 4.410
Sept 4.750 0.503 4.150
Oct 4.730 0.595 3.450
Nov 4.030 0.611 3.360
Dec 3.490 0.585 3.700
7 0.7
e N w
Daily solar radiation (kWh/m2/day)
A
6 0.6
5 0.5
0.4
0.3
0.2
0.1
0 0
RY A` & N x
& Ś w XS SS yw” & Š s $
E Solar Energy (SE) (kWh/m2/day) — Clearness Index
Figure 3. Monthly average solar irradiance throughout the
year
&
& oa
& & ys SF SF F
uw
a
N
Average wind speed (m/s)
w
m
o
we
Figure 4. Monthly average wind speed throughout the year
14
U. Singh, M. Rizwan/Future Energy
2.3 Assessment of biomass energy resource potential at
the selected location
In Sarai Jairam village animal dung may be simply used
to produce biogas through the digestion and combustion
processes, respectively. Anaerobic digesters are used to treat
the manure produced by cattle and produce power. The total
dung produced annually from the community is calculated by
equation (1);
Mn = yy Njmj (1)
Where Mn is the annual total amount of manure produced, Nj
is the number of the selected group of animals, n is the overall
number of cattle and mj shows manure produced per cattle
[21].
Table 2 lists the number of animals and the availability of
animal manure in the village of Sarai Jairam. The total amount
of manure produced by all the animals is estimated to be
6.425 tons/day, which may be used to produce 166667.76
kWh of power annually. The total potential of biomass is
shown in Figure 5.
Table 2. Total amount of manure produced by all animals
Description Number Dung Dung availability
of (kg/day/cattle) (kg/day)
animals
Buffaloes 310 15 4650
Cow 175 10 1750
Goat 25 1 25
nN WwW FB WU aA N
Available biomass (ton/day)
=
o
SS pr O K&
WU
eo S
RX
Figure 5. Technical potential of biomass (animal manure)
3. Assessment of Electrical Load
In this work, a hybrid system that employs energy from
solar and biogas has been designed to meet the electrical
demands of one Primary school, Junior school and Panchayat
ghar. The panchayat ghar has two rooms with two fans and
four tube lights. The primary school contains six rooms with
twelve fans, twelve tube lights, two computers, and one
submersible pump, while, five rooms, ten fans, ten tube lights,
two computers, and one submersible pump make up the
junior high school. Table 3 provides the quantity, power
ratings, and power consumption for each load. Figure 6
depicts the electricity load of the proposed region taking into
account future expansion. The data has been gathered from
the school and panchayat ghar employees.
4. System Design and Assessment
The system configuration shown in Figure 7 includes a
PV panel, biogas engine generator, and battery storage with a
bidirectional converter. An electric load and biogas generator
are connected to the AC bus. The battery storage and PV
May 2023| Volume 02 | Issue 02| Pages 12-20
module are connected to the DC bus. Additionally, the
converter is coupled with the AC and DC buses. Table 4 shows
the technical specifications and capital costs of components.
Table 3. Electricity load calculation for the selected
communities
S.no. 1 2 3 4
Load Fan Tube | Computer | Water
light pump
Power rating (watts) 60 30 100 500
Panchayat | No. in use 2 4 0 0
ghar
Utilization 10 10 0 0
hours
Primary No. in use 12 12 2 1
school
Utilization 8 8 8 1
hours
Junior No. in use 10 10 2 1
school
Utilization 8 8 8 1
hours
Total energy 11760 | 6480 3200 1000
Consumed (Watt)
Total load 22.440kWh
Seasonal Profile
3
2
z
>
1
0
fesse esr eared
Figure 6. Monthly load profile during the whole year
0 DC Bus AC Bus
ttha :
PV Array
| Biogas Genset
Power
Coverter
Battery
AC Loads
24.00 LWhid
3.60 kW peak
Figure 7. Configuration of off-grid hybrid PV-biogas system
5. Results and Discussion
5.1 System sensitivity analysis outcomes
For technical and economical assessment purposes, the
system must be designed with certain constraints or control
variables that have an impact on the operating costs and
output of the HRES system. Because the developed system is
sustainable and the possibilities like the changes in solar
15
U. Singh, M. Rizwan/Future Energy
radiations and biomass supply were taken into account for
the sensitivity analysis. Since animal dung is a free source of
biomass, hence, the biomass price was not considered in the
system design. It enables planners and designers to select a
very efficient and cost-effective method for the specified
design parameters. To find out how variations in solar
radiation and biomass supply might affect the system
economy, both variables were varied. As the supplied
biomass was 6.43 tonnes per day, it varied between 6.43-6.50
tonnes per day for the sensitivity analysis, and the solar
radiation varied between 4.91-4.99 kWh/m2/day.
Table 4. Technical specifications and cost of components
Hybrid Specifications Value
system
components
Solar PV Capital cost 650$/kW
O&M cost 1$/kW
Replacement 0$/kW
cost
Sizes 0,1,1.5,2,2.5,3,3.5,4,4.5,5,6,7,
7.5,8,9,10
Tracking system No
Ground 20%
reflectance
Derating factor 80%
Life span 25 years
Azimuth,Slope 0
Converter Capital cost 190$/kW
Replacement 190$/kW
cost
Sizes 0,1,1.5,2,2.5,3,3.5,4,4.5,5
Rectifier 85%
efficiency
Capaicity 100%
relative to
inverter
Inverter 95%
efficiency
Life span 20 years
Annual rate of 0%
interest
Battery Capital cost 150$/kW
Replacement 30$/kW
cost
Nominal 1kWh
capacity
Float life 5 years
Round trip 80%
efficiency
Mninmum state 40%
of charge
Lifetime 917kWh
throughput
Biogas Capital cost 250$/kW
generator O&M cost 0.08$/kW
Sizes 0, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5
Replacement 150$/kW
cost
Biomass cost $3.75/tone
Lowest load 30%
ratio
Life span 20000 hours
May 2023] Volume 02 | Issue 02| Pages 12-20
The sensitivity analysis outcomes of the HRE system are
displayed in Table 5, which highlights how changes in the
supply of biomass and solar radiation affect the NPC, COE, and
operating costs. The findings reveal that as biomass is
increased and solar radiation changes are taken into account,
net present and operating costs also rise.
5.2 System optimization outcomes
The developed hybrid Photovoltaic/biogas system with
sensitivity inputs was modeled in HOMER Pro software by
ranging the potential of the biogas generator and solar
radiance in order to determine the most efficient, optimized,
and cost-effective system for the Primary school, Junior
school, and Panchayat ghar in rural areas. To maximize the
system's ability to meet the electricity demand, the capacity
range of the biomass generator varied between 1kW to 5 kW,
while the capacity range of the PV system varied between
4kW to 6 kW. In this study, a 1.50 kW biogas generator, a 5
kW PV array, a 3.25 kW converter, and 30 storage batteries
were the optimal and most economically viable
configurations evaluated for the hybrid system. This
configuration is depicted in Figure 9.
The developed hybrid Photovoltaic/biogas system with
sensitivity inputs was modeled in HOMER Pro software by
ranging the potential of the biogas generator and solar
radiance in order to determine the most efficient, optimized,
and cost-effective system for the Primary school, Junior
school, and Panchayat ghar in rural areas. To maximize the
system's ability to meet the electricity demand, the capacity
range of the biomass generator varied between 1kW to 5 kW,
while the capacity range of the PV system varied between
4kW to 6 kW. In this study, an 1.50 kW biogas generator, 5 kW
PV array, a 3.25 kW converter and 30 storage batteries were
the optimal and most economically viable configurations
evaluated for the hybrid system. This configuration is
depicted in Fig. 9. As NPC, COE, and beginning capital
investment are used to sort HOMER's optimum results. The
total capital cost, NPC and COE for the best optimized PV-
Biogas configuration are, respectively $8,743, $57,283, and
$0.614. Other designs with varying equipment sizing that can
meet the same energy load have low initial capital costs but
high NPC, COE, and operating costs over the lifetime of the
project. The various system designs with their significant
economic parameters are shown in Table 6.
Table 7 also depicts the share of power production of each
component throughout a year, total electricity production,
renewable percentage, and excess electricity with unmet load
for all different system designs. Figure 8 depicts the average
monthly electricity production from a hybrid PV-Biogas
system, where orange bars show the power supplied by the
photovoltaic panel and green bars show the power generated
by a biogas generator. The total initial cost is calculated at
$8,743 as shown in Table 6. This is the first investment
needed to start the project. The initial cost of Lead acid
battery and photovoltaic panels are more as compared to
other components as shown in Figure 9. This higher cost is a
result of the substantial battery storage capacity, which is
intended to offer reliable electricity dispatch when the
electricity produced by the power systems is not enough to
fulfill the load.
16
U. Singh, M. Rizwan/Future Energy
Table 5 Sensitivity outcomes for the hybrid PV/biogas system
May 2023] Volume 02 | Issue 02/ Pages 12-20
Sensitivity Architecture Cost
Solar Scaled Bioma PV Bio 1kWh_ Converter NPC ($) COE ($) Operating cost Initial capital ($)
Average ss (kW) (kW) LA (kW) ($/yr)
(kWh/mA?/day) Scaled
Averag
e (t/d)
4.91 6.43 5 1.5 30 3.25 57283 0.614 4547 8743
4.92 6.44 5 1.5 32 3.25 56901 0.610 4483 9043
4.95 6.46 5 1.5 32 3.25 55964 0.600 4396 9043
4.97 6.48 5 1.5 32 3.26 55345 0.594 4337 9044
4.99 6.5 5 1.5 32 3.25 54762 0.587 4283 9043
Table 6 Various different optimized system configurations with economic parameters.
Various Configuration NPC ($) COE ($) Operating Cost ($) Initial Cost ($)
PV/Biogas/Battery/Converter 57283 0.6145 4547 8743
PV/Biogas/Converter 169188 1.8107 15458 4178
Biogas/Battery/Converter 213798 2.3475 19884 1539
Biogas 260688 2.8009 24362 625
Table 7 Electricity generation of different feasible system designs
Parameters PV/Biogas/Battery/ PV/Biogas/ Biogas/Battery/ Biogas
Converter Converter Converter
PV array (kWh/year) 7,868 (81.1%) 7,868 (56.2%) 2 =
Biogas generator (kKWh/year) 1,830 (18.9%) 6,128 (43.8%)
9,013 (100%) 10,185 (100%)
Total electricity generation 9,698 (100%) 13,996 (100%) 9,013 (100%) 10,185 (100%)
(kWh/year)
Renewable fraction (%) 100 100 100 0
Capacity shortage (kKWh/year) 0.212 (0%) 143 (1.63%)
2.11 (0.1%) 111 (1.27%)
Excess electricity (kKWh/year) 65.0 (0.67%) 5,055 (36.1%) 0 1,466 (14.4%)
Unmet electric load 0.0000267 (0%) 6.77 (0.0773%) 1.10 (0%) 41.0 (0.468%)
(kWh/year)
Monthly average electricity production
mpv 1
meio 23
7
= 05
= 04
0.3
0.2
0.1
0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Figure 8. Monthly average electricity generation from the hybrid system
17
U. Singh, M. Rizwan/Future Energy
4500
— 4000
2 3500
H 3000
(5}
E 2500
% 2000
vo
È 1500
© 1000
z
500 q
0
Capital O&M Replacement Salvage
Category
m Generic 1kWh Lead Acid m Generic Biogas Genset (size-your-own)
Generic flat plate PV E System Converter
Figure 9. Cost summary of the hybrid PV/Biogas system
In addition, the photovoltaic panels, which are less
expensive once installed than a biogas generator, as biomass
is available for free, which is why the fuel category has not
been presented. Figure 10 displays the power generated by
each component, and the total electrical load served is
represented in the above plot, while the lower plot shows the
unmet electrical load, total renewable power output, ac
primary load served, input power, and state of charge of
battery over the course of July 9 to July 18 to help with a better
understanding of how the system operates.
Table 8 and Figure 8 make it clear that the photovoltaic
system consistently outperforms biogas in terms of electricity
production. Being off the grid, the system uses solar and
biogas as resources to meet the load demands because our
maximum demand hours are during the daytime for
community load (schools and panchayat ghar) purposes. The
capacity factor of the PV modules is about 81.1%, and it
operates throughout the year depending on load
requirements, producing about 7,868 kWh/year, compared to
1,830 kWh/year from the biomass generator having a
capacity factor of 18.9%. Due to the lack of biomass
availability throughout the day, biogas power generation is
reduced. Furthermore, the system is producing more power
than it needs to satisfy its annual power usage of 8,733 kWh,
which can be saved or used for other productive purposes.
6. Conclusion
This study offers a technical and economical assessment
of different stand-alone solutions for Primary school, Junior
school, and Panchayat Ghar buildings of Sarai Jairam village
in Uttar Pradesh, India. HOMER pro analyzed several hybrid
PV-biogas system configurations by modeling a dynamic
hybrid model. An ideal solution was suggested based on the
cost analysis after these hybrid designs underwent sensitivity
analysis using variables such as solar radiation, biomass
resource, and system sizing. In this study, the combination of
a 1.50 kW biogas generator, 5 kW PV array, a 3.25 kW
converter, and 30 storage batteries was found to be the most
cost-effective option with a total capital cost of $8,743, Net
Present Cost (NPC) of $57,283 and Cost of Energy (COE)
$0.61, respectively. This hybrid renewable energy system
produces roughly 9,698 kWh per year, with an additional 965
kWh per year being generated to make the study area grid-
independent. Additionally, the system has an estimated
payback period of 0.41 years and a favorable net current cost
for a projection timeframe of 25 years. By providing rural
areas with these hybrid renewable energy systems, the Indian
May 2023] Volume 02 | Issue 02| Pages 12-20
government may significantly contribute to resolving the
country's current energy crisis. Additionally, the existing
legislation that supports the use of such systems only offers
tax breaks or reductions, which is insufficient to allow low-
income populations to make use of these systems. The
government may alter its supporting policies, offer rewards
for system employment, and launch a national electrification
campaign. Similar studies could be undertaken for other rural
places in order to electrify them, which would also help the
Indian government achieve its goal of "Power to all."
Table 8. Annual generation and consumption of electricity by
a hybrid system
Generation | kWh/year | % Consumption | kWh/year | %
PV 7,868 81.1 | AC primary | 8,733 100
Modules load
Biogas 1,830 18.9 | DC primary | 0 0
Generator load
Total 9,698 100 | Total 8,733 100
Ethical issue
The authors are aware of and comply with best practices in
publication ethics, specifically with regard to authorship
(avoidance of guest authorship), dual submission,
manipulation of figures, competing interests, and compliance
with policies on research ethics. The authors adhere to
publication requirements that the submitted work is original
and has not been published elsewhere.
Data availability statement
Datasets analyzed during the current study are available and
can be given following a reasonable request from the
corresponding author.
Conflict of interest
The authors declare no potential conflict of interest.
Author contributions
Mohammad Rizwan: Conceptualization and supervised the
research; Upma Singh: Methodology; resources; validation;
formal analysis; writing the original draft. Both authors
contributed to the analysis of the findings, critically reviewed
and edited the manuscript, and approved the final version for
submission.
Funding
No specific grant has been given to this research by any
funding agency/organizations.
18
U. Singh, M. Rizwan/Future Energy May 2023] Volume 02 | Issue 02| Pages 12-20
[Generic flat plate PV Power Output
EAC Primary Load Served
H Generic Biogas Genset (size-your-own) Pow
Wotsi Electrical Load Served
Hurmet Electrical Load
Dior Renewable Power Output
E Generic 1KWh Lead Acid Input Power
H Generic 1KWh Lead Acid State of Charge
kw
lt ry
Lur Jy
KIN
KAA
Yat py
4at 75
“ut Jy
KIN
Generic 1kWh Lead Acid State of Charge (%)
“ut 75
KA
Ari
4 7,
KA
KIN
iS =
> >
x y
Figure 10. Total electrical load served, unmet electrical load, total renewable power output, state of charge of the battery, ac
primary load served and generated power by each component during July 9 to July 18.
References
[1] K. Kusakana, J. L. Munda, and A. A. Jimoh, Feasibility [7] S. Iqbal, M. U. Jan, A. U. Rehman, A. Shafiq, H. U.
study of a hybrid PV-micro hydro system for rural Rehman, and M. Aurangzeb, Feasibility Study and
electrification, In AFRICON 2009, IEEE, Sep. 2009, pp. Deployment of Solar Photovoltaic System to Enhance
1-5. Energy Economics of King Abdullah Campus University
[2] F. Rinaldi, F. Moghaddampoor, B. Najafi, and R. of Azad Jammu and Kashmir Muzaffarabad, AJK
Marchesi, Economic feasibility analysis and Pakistan, IEEE Access, 10, 2022, pp.5440-5455.
optimization of hybrid renewable energy systems for [8] Q. Ma, X. Huang, F. Wang, C. Xu, R. Babaei, and H.
rural electrification in Peru, Clean technologies and Ahmadian, Optimal sizing and feasibility analysis of
environmental policy, 23(3), 2021, pp.731-748 grid-isolated renewable hybrid microgrids: Effects of
[3] J. Ahmed, K. Harijan, P. H. Shaikh, and A. A. Lashari, energy management controllers, Energy, 240, 2022,
A.A., Techno-economic feasibility analysis of an off- p.122503.
grid hybrid renewable energy system for rural [9] F. Eze, J. Ogola, R. Kivindu, M. Egbo, and C. Obi,
electrification, Journal of Electrical and Electronic Technical and economic feasibility assessment of
Engineering, 9(1), 2021, pp.7. hybrid renewable energy system at Kenyan
[4] A.K. Awopone, A.K., Feasibility analysis of off-grid institutional building: A case study, Sustainable Energy
hybrid energy system for rural electrification in Technologies and Assessments, 51, 2022, pp.101939.
Northern Ghana, Cogent Engineering, 8(1), 2021, [10] M. M. Seedahmed, M. A. Ramli, H. R. Bouchekara, M. S.
pp.1981523. Shahriar, A. H. Milyani, and M. Rawa, A techno-
[5] F. Rashid, M. E. Hoque, M. Aziz, T. N. Sakib, M. T. Islam, economic analysis of a hybrid energy system for the
and R. M. Robin, Investigation of optimal hybrid energy electrification of a remote cluster in western Saudi
systems using available energy sources in a rural area Arabia, Alexandria Engineering Journal, 61(7), 2022,
of Bangladesh, Energies, 14(18), 2021, p.5794. pp.5183-5202.
[6] A.H. Eisapour, K. Jafarpur, and E. Farjah, Feasibility [11] F. Odoi-Yorke, S. Abaase, M. Zebilila, and L. Atepor, L.,
study of a smart hybrid renewable energy system to Feasibility analysis of solar PV/biogas hybrid energy
supply the electricity and heat demand of Eram system for rural electrification in Ghana, Cogent
Campus, Shiraz University; simulation, optimization, Engineering, 9(1), 2022, pp. 2034376.
and sensitivity analysis, Energy Conversion and [12] E.S. Bayu, B. Khan, I. G. Hagos, O. P. Mahela, and J. M.
Management, 248, 2021, pp.114779. Guerrero, Feasibility Analysis and Development of
Stand-Alone Hybrid Power Generation System for
Remote Areas: A Case Study of Ethiopian Rural Area,
Wind, 2(1), 2022, pp.68-86.
19
U. Singh, M. Rizwan/Future Energy
[13]
[14]
[15]
[16]
[18]
P. C. Okonkwo, E. M. Barhoumi, W. Emori, M. I.
Shammas, P. C. Uzoma, A. M. Amer Mohamed, and A. M.
Abdullah, Economic evaluation of hybrid electrical
systems for rural electrification: A case study of a rural
community in Nigeria, International Journal of Green
Energy, 19(10), 2022, pp.1059-1071.
N. S. D. Ladu, R. Samikannu, K. G. Gebreslassie, M.
Sankoh, L.E. R Hakim, A. Badawi, and T. P..B Latio,
T.P.B., Feasibility study of a standalone hybrid energy
system to supply electricity to a rural community in
South Sudan, Scientific African, 16, 2022, p.e01157.
F. J. Montero, R. Kumar, R. Lamba, R. A. Escobar, M.
Vashishtha, S. Upadhyaya, and A. M. Guzmán, Hybrid
photovoltaic-thermoelectric system: Economic
feasibility analysis in the Atacama Desert, Chile,
Energy, 239, 2022, p.122058.
L. Uwineza, H. G. Kim, and C. K. Kim, Feasibility study
of integrating the renewable energy system in Popova
Island using the Monte Carlo model and HOMER,
Energy Strategy Reviews, 33, 2021, p.100607.
A. Tazay, Techno-economic feasibility analysis ofa
hybrid renewable energy supply options for university
buildings in Saudi Arabia, Open Engineering, 11(1),
2021, pp.39-55.
M. A. V. Rad, R. Ghasempour, P. Rahdan, S. Mousavi,
and M. Arastounia, Techno-economic analysis of a
hybrid power system based on the cost-effective
hydrogen production method for rural electrification, a
case study in Iran. Energy, 190, 2020, p.116421.
[19]
[20]
[21]
[22]
20
May 2023] Volume 02 | Issue 02| Pages 12-20
O. Babatunde, I. Denwigwe, O. Oyebode, D. Ighravwe, A.
Ohiaeri, and D. Babatunde, Assessing the use of hybrid
renewable energy system with battery storage for
power generation in a University in Nigeria,
Environmental Science and Pollution Research, 29(3),
2022, pp.4291-4310.
L. Ji, Z. Liu, Y. Wu, and G. Huang, Techno-economic
feasibility analysis of optimally sized a
biomass/PV/DG hybrid system under different
operation modes in the remote area, Sustainable
Energy Technologies and Assessments, 52, 2022,
p.102117.
D. T. Hermann, N. Donatien, T. K. F. Armel, and T. René,
Techno-economic and environmental feasibility study
with demand-side management of
photovoltaic/wind/hydroelectricity/battery/diesel: A
case study in Sub-Saharan Africa, Energy Conversion
and Management, 258, 2022, p.115494.
A. Shiroudi, S. R. H. Taklimi, S. A. Mousavifar, and P.
Taghipour, Stand-alone PV-hydrogen energy system in
Taleghan-Iran using HOMER software: optimization
and techno-economic analysis, Environment,
development and sustainability, 15(5), 2013, pp.1389-
1402.